Welcome to LookChem.com Sign In|Join Free

CAS

  • or

18751-58-1

Post Buying Request

18751-58-1 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

18751-58-1 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 18751-58-1 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 1,8,7,5 and 1 respectively; the second part has 2 digits, 5 and 8 respectively.
Calculate Digit Verification of CAS Registry Number 18751-58:
(7*1)+(6*8)+(5*7)+(4*5)+(3*1)+(2*5)+(1*8)=131
131 % 10 = 1
So 18751-58-1 is a valid CAS Registry Number.

18751-58-1SDS

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 17, 2017

Revision Date: Aug 17, 2017

1.Identification

1.1 GHS Product identifier

Product name tert-butylperoxy(triphenyl)silane

1.2 Other means of identification

Product number -
Other names t-Butylperoxytriphenylsilan

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

More Details:18751-58-1 SDS

18751-58-1Relevant articles and documents

Determination of silyl peroxides by ultra-performance liquid chromatography/electrospray ionisation mass spectrometry

Krawczyk, Tomasz,Zalewski, Mariusz,Szo?tysik, Rafa?,Korytkowska-Wa?ach, Anna

, p. 2040 - 2046 (2018/11/10)

Rationale: Residual initiators in polymers are a concern in the case of products that come directly into contact with the human body or food. Due to low concentrations and difficulties in the sample preparation, highly sensitive and selective methods are required. Methods: A series of bis-silyl- and alkyl-silyl peroxides were analysed by electrospray ionisation mass spectrometry (ESI-MS) on an ultra-performance liquid chromatography/time-of-flight (UPLC/TOF) instrument. Li, Na, K, and NH4 acetates were used to promote the formation of [M + Me]+ ions. The sample preparation involved only dissolution of the polymer sample in 0.1 mL of acetonitrile, followed by precipitation with 1 mL of water. A portion of 0.1–1 μL of the solution was then analysed without further treatment by UPLC/ESI-MS. Results: Limits of detection (LODs) were in the range of 0.06–9 pmol, depending on the peroxide structure. On average, the signal intensity increased with the number of phenyl groups in a peroxide and decreased in the order Na > Li > K > NH4. Peroxides that did not contain phenyl groups could not be detected. Collision-induced dissociation experiments can be used for structural investigations of alkyl-silyl peroxides. It was possible to detect 2 × 10?4% (LOD = 7 × 10?5%) of unreacted Ph3SiOOt-Bu in the poly(methyl methacrylate) sample. Conclusions: The method is suitable for the analysis of trace peroxide initiators in polymers and for other purposes where LODs in the pmol range are required.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 18751-58-1