Welcome to LookChem.com Sign In|Join Free

CAS

  • or

337917-95-0

Post Buying Request

337917-95-0 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

337917-95-0 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 337917-95-0 includes 9 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 6 digits, 3,3,7,9,1 and 7 respectively; the second part has 2 digits, 9 and 5 respectively.
Calculate Digit Verification of CAS Registry Number 337917-95:
(8*3)+(7*3)+(6*7)+(5*9)+(4*1)+(3*7)+(2*9)+(1*5)=180
180 % 10 = 0
So 337917-95-0 is a valid CAS Registry Number.

337917-95-0Relevant articles and documents

Synthesis of a terbium fluorescent chelate and its application to time-resolved fluoroimmunoassay

Yuan,Wang,Majima,Matsumoto

, p. 1869 - 1876 (2001)

A new nonadentate ligand, N, N, Nl, N1-[2,6-bis(3′aminomethyl-1′-pyrazolyl)-4- phenylpyridine]tetrakis(acetic acid) (BPTA) for a Tb3+ fluorescent complex was synthesized. The Tb3+ complex is strongly fluorescent, having a large fluorescence quantum yield of 1.00 and very long fluorescence lifetime of 2.681 ms in 0.05 M borate buffer of pH 9.1. Streptavidin (SA) was labeled with BPTA by using its succinimidyl monoester, and the BPTA-Tb3+-labeled SA was used in sandwich-type time-resolved fluoroimmunoassay (TR-FIA) of α-fetoprotein (AFP) and carcinoembryonic antigen (CEA) in human sera. The Tb3+-labeled SA was also used in competitive-type TR-FIA of bensulfuron-methyl (BSM) in water. The detection limits of these assays are 42 pg/mL for AFP, 70 pg/mL for CEA, and 0.4 ng/mL for BSM. In addition, a new simultaneous measurement method for AFP and CEA in a human serum sample was developed by using 4,4′-bis(l″,1″,1″,2″,2″,3″,3″ -heptafluoro-4″,6″-hexanedion-6″-yl)chlorosulfo-o-terphenyl (BHHCT)-Eu3+-labeled anti-AFP antibody, biotinylated anti-CEA antibody, and BPTA-Tb3+-labeled SA. The concentrations of AFP and CEA in 39 human serum samples were determined, and the results were compared with those of the independently determined AFP and CEA by TR-FIA with a single-label method. A good correlation was obtained with the correlation coefficients of 0.991 for AFP and 0.994 for CEA.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 337917-95-0