Add time:08/28/2019 Source:sciencedirect.com
The development of a reversed-phase liquid chromatographic method, using a mobile phase containing a mixture of anion and cation ion-pairing agents and a base-deactivated octyldecylsilyl column as stationary phase, is described for the control of all known impurities in (Z)-Chlorprothixene (cas 113-59-7) hydrochloride (bulk drug). Validation of the method showed it to be reproducible, selective for both (Z) chlorprothixene hydrochloride and its E-isomer, accurate and linear over the concentration range of analysis with a limit of detection of 0.3 μg ml−1.
We also recommend Trading Suppliers and Manufacturers of Chlorprothixene (cas 113-59-7). Pls Click Website Link as below: cas 113-59-7 suppliers