 Model AA320N Atomic Absorption Spectrophotometer
  • Model AA320N Atomic Absorption Spectrophotometer
  • Specifications of AA320N Atomic Absorption Spectrophotometer:

    1. Characteristics A

    1). Build-in computer data processing and LCD: Adopting highly integrated micro digital circuit, which id stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. it is equipped with interface for externally linking PC.

    2). Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp need not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

    3). High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.

    4). Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.

    5). Long-life and anti-corrosive atomization system: The burner id made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

    6). Multi-functional analysis mode: For methods of flame absorption, flame emission, furnace atomic absorption and hydride generation.

    7). Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as -acetylene flame and extend the analytic elements to reach more than 60.

    8). Complete set of accessories: To be supplied with the instrument and ready for use after they are purchased.

    2. Characteristics B

    1). Light-source system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply: with fixed current

    2). Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm

    3). Flame atomization system: Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.

    4). Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curves fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

    3. Technical Specifications

    Working Spectral Range

    190~900nm

    Wavelength Accuracy

    ≤±0.5nm

    Wavelength Repeatability

    ≤0.3nm (single direction)

    Spectrum Bandwidth

    0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

    Resolution

    <40%

    Base Line Stability

    ±0.004Abs/30min

    Characteristic Concentration of

    ≤0.04μg/ml/1%

    Detection Limit of Copper

    ≤0.008μg/ml

    Background Calibration Ability

    Greater than 30 times.

    Standby Interface

    RS232

    Instrument Power Supply

    220V, 3A, 50Hz