Welcome to LookChem.com Sign In|Join Free

CAS

  • or

174095-91-1

Post Buying Request

174095-91-1 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

174095-91-1 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 174095-91-1 includes 9 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 6 digits, 1,7,4,0,9 and 5 respectively; the second part has 2 digits, 9 and 1 respectively.
Calculate Digit Verification of CAS Registry Number 174095-91:
(8*1)+(7*7)+(6*4)+(5*0)+(4*9)+(3*5)+(2*9)+(1*1)=151
151 % 10 = 1
So 174095-91-1 is a valid CAS Registry Number.

174095-91-1Relevant articles and documents

Utilization of self-sorting processes to generate dynamic combinatorial libraries with new network topologies

Saur, Isabelle,Scopelliti, Rosario,Severin, Kay

, p. 1058 - 1066 (2006)

The synthesis of water-soluble, organometallic macrocycles is described. They were obtained by self-assembly in reactions of the half-sandwich complexes [{Ru(C6H5Me)Cl2}2], [{Ru(p-cymene)Cl2}2/s

Prediction of 3-hydroxypyridin-4-one (HPO) log K1 values for Fe(iii)

Chen, Yu-Lin,Barlow, Dave J.,Kong, Xiao-Le,Ma, Yong-Min,Hider, Robert C.

, p. 10784 - 10791 (2013/01/14)

As a means to aid in the design of 3-hydroxypyridin-4-ones (HPOs) intended for use as therapeutic Fe3+ chelating agents, a novel methodology has been developed using quantum mechanical (QM) calculations for predicting the iron binding affinities of the compounds (more specifically, their log K 1 values). The reported/measured HPO log K1 values were verified through their correlation with the corresponding sum of the compounds' ligating group pKa values. Using a training set of eleven HPOs with known log K1 values, reliable predictions are shown to be obtained with QM calculations using the B3LYP/6-31+G(d)/CPCM model chemistry (with Bondi radii, and water as solvent). With this methodology, the observed log K 1 values for the training set compounds are closely matched by the predicted values, with the correlation between the observed and predicted values giving r2 = 0.9. Predictions subsequently made by this method for a test set of 42 HPOs of known log K1 values gave predicted values accurate to within ±0.32 log units. In order to further investigate the predictive power of the method, four novel HPOs were synthesised and their log K1 values were determined experimentally. Comparison of these predicted log K1 values against the measured values gave absolute deviations of 0.22 (13.87 vs. 14.09), 0.02 (14.31 vs. 14.29), 0.12 (14.62 vs. 14.50), and 0.13 (15.04 vs. 15.17). The prediction methodology reported here is the first to be provided for predicting the absolute log K1 values of iron-chelating agents in the absence of pKa values.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 174095-91-1