Welcome to LookChem.com Sign In|Join Free

CAS

  • or

69220-40-2

Post Buying Request

69220-40-2 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

69220-40-2 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 69220-40-2 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 6,9,2,2 and 0 respectively; the second part has 2 digits, 4 and 0 respectively.
Calculate Digit Verification of CAS Registry Number 69220-40:
(7*6)+(6*9)+(5*2)+(4*2)+(3*0)+(2*4)+(1*0)=122
122 % 10 = 2
So 69220-40-2 is a valid CAS Registry Number.

69220-40-2SDS

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 12, 2017

Revision Date: Aug 12, 2017

1.Identification

1.1 GHS Product identifier

Product name 4-chloro-10H-acridin-9-one

1.2 Other means of identification

Product number -
Other names 4-Chlor-10H-acridin-9-on

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

More Details:69220-40-2 SDS

69220-40-2Upstream product

69220-40-2Relevant articles and documents

Simultaneous identification of Fenton degradation by-products of diclofenac, ibuprofen and ketoprofen in aquatic media by comprehensive two-dimensional gas chromatography coupled with mass spectrometry

Beldean-Galea, Mihail Simion,Coman, Virginia,Copaciu, Florina,Thiébaut, Didier,Vial, Jér?me

, p. 1021 - 1027 (2015/07/15)

Diclofenac, ibuprofen and ketoprofen are anti-inflammatory drugs intensively used both in human and animal treatment. Due to their high stability these compounds are partially removed by wastewater treatment plants and from this reason the development of some alternative treatments such as advanced oxidative processes are necessary. The main problems in the optimization of an advanced oxidative process rise from the difficulties which appear in the identification of degradation by-products necessary for the establishment of degradation pathway. In this paper a developed method for the simultaneous identification of Fenton degradation by-products of the three above mentioned pharmaceuticals is presented. The obtained results show the comprehensive two-dimensional gas chromatography coupled with mass spectrometry as a proper method for the analysis of the complex mixture of compounds resulted from the Fenton degradation process. Moreover, some compounds never mentioned in the scientific literature were identified. (Chemical Equation Presented).

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 69220-40-2