Product name
CAS-No.
:
:
Mercury(II) iodate
7783-32-6
1.2
Relevant identified uses of the substance or mixture and uses advised against
Identified uses
:
Laboratory chemicals, Manufacture of substances
2.
2.1
2.2
HAZARDS IDENTIFICATION
Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 [EU-GHS/CLP]
Acute toxicity, Inhalation (Category 2)
Acute toxicity, Dermal (Category 1)
Acute toxicity, Oral (Category 2)
Specific target organ toxicity - repeated exposure (Category 2)
Acute aquatic toxicity (Category 1)
Chronic aquatic toxicity (Category 1)
Classification according to EU Directives 67/548/EEC or 1999/45/EC
Very toxic by inhalation, in contact with skin and if swallowed. Danger of cumulative effects. Very toxic to
aquatic organisms, may cause long-term adverse effects in the aquatic environment.
Label elements
Labelling according Regulation (EC) No 1272/2008 [CLP]
Pictogram
Signal word
Hazard statement(s)
H300
H310
H330
H373
H410
Precautionary statement(s)
P260
P264
P273
P280
P284
P301 + P310
Supplemental Hazard
Danger
Fatal if swallowed.
Fatal in contact with skin.
Fatal if inhaled.
May cause damage to organs through prolonged or repeated exposure.
Very toxic to aquatic life with long lasting effects.
Do not breathe dust/ fume/ gas/ mist/ vapours/ spray.
Wash hands thoroughly after handling.
Avoid release to the environment.
Wear protective gloves/ protective clothing.
Wear respiratory protection.
IF SWALLOWED: Immediately call a POISON CENTER or doctor/
physician.
none
Statements
According to European Directive 67/548/EEC as amended.
Hazard symbol(s)
R-phrase(s)
R26/27/28
R33
R50/53
Very toxic by inhalation, in contact with skin and if swallowed.
Danger of cumulative effects.
Very toxic to aquatic organisms, may cause long-term adverse effects in
the aquatic environment.
S-phrase(s)
S13
S28
S45
S60
S61
Keep away from food, drink and animal feedingstuffs.
After contact with skin, wash immediately with plenty of soap and water.
In case of accident or if you feel unwell, seek medical advice immediately
(show the label where possible).
This material and its container must be disposed of as hazardous waste.
Avoid release to the environment. Refer to special instructions/ Safety
data sheets.
2.3
3.
3.1
Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS
Substances
Formula
Molecular Weight
Component
Mercury diiodate
:
:
HgI2O6
550,4 g/mol
Concentration
4.
4.1
CAS-No.
EC-No.
FIRST AID MEASURES
Description of first aid measures
7783-32-6
231-989-9
-
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2
4.3
5.
5.1
5.2
5.3
5.4
6.
6.1
6.2
6.3
6.4
7.
7.1
7.2
7.3
8.
8.1
8.2
9.
9.1
Most important symptoms and effects, both acute and delayed
Tremors, fatigue, Anorexia., Hallucinations., Headache, Nausea, Vomiting
Indication of immediate medical attention and special treatment needed
no data available
FIRE-FIGHTING MEASURES
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Hydrogen iodide, Mercury/mercury oxides.
Precautions for fire-fighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available
ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Wear respiratory protection. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate
ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the
environment must be avoided.
Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire
protection.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Specific end uses
no data available
EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the
product.
Personal protective equipment
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the
standard EN 374 derived from it.
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such as
NIOSH (US) or CEN (EU).
PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
a)
b)
c)
d)
e)
f)
g)
h)
Appearance
Odour
Odour Threshold
pH
Melting/freezing point
Initial boiling point and
boiling range
Flash point
Evaporation rate
Form: powder
Colour: white
no data available
no data available
no data available
Melting point/range: 175 °C
no data available
not applicable
no data available
i)
Flammability (solid, gas) no data available
j)
k)
l)
Upper/lower
flammability or
explosive limits
Vapour pressure
Vapour density
no data available
no data available
no data available
m) Relative density
no data available
n)
o)
p)
q)
r)
s)
t)
Water solubility
Partition coefficient: n-
octanol/water
Autoignition
temperature
Decomposition
temperature
Viscosity
Explosive properties
Oxidizing properties
no data available
no data available
no data available
no data available
no data available
no data available
no data available
9.2
10.
10.1
10.2
10.3
10.4
10.5
10.6
11.
11.1
Other safety information
no data available
STABILITY AND REACTIVITY
Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Strong oxidizing agents, Reducing agents
Hazardous decomposition products
Other decomposition products - no data available
TOXICOLOGICAL INFORMATION
Information on toxicological effects
Acute toxicity
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
This product is or contains a component that is not classifiable as to its carcinogenicity based on its IARC,
ACGIH, NTP, or EPA classification.
IARC:
IARC:
No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
3 - Group 3: Not classifiable as to its carcinogenicity to humans (Mercury diiodate)
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
May cause damage to organs through prolonged or repeated exposure.
Aspiration hazard
no data available
Potential health effects
Inhalation
Ingestion
Skin
Eyes
May be fatal if inhaled. May cause respiratory tract irritation.
May be fatal if swallowed.
May be fatal if absorbed through skin. May cause skin irritation.
May cause eye irritation.
Signs and Symptoms of Exposure
Tremors, fatigue, Anorexia., Hallucinations., Headache, Nausea, Vomiting
Additional Information
RTECS: Not available
12.
12.1
12.2
12.3
12.4
12.5
12.6
13.
13.1
14.
14.1
ECOLOGICAL INFORMATION
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
no data available
Other adverse effects
Very toxic to aquatic life.
DISPOSAL CONSIDERATIONS
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional
waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent
and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.
TRANSPORT INFORMATION
UN-Number
14.2
ADR/RID: 2025
UN proper shipping name
IMDG: 2025
IATA: 2025
ADR/RID:
IMDG:
IATA:
MERCURY COMPOUND, SOLID, N.O.S. (Mercury diiodate)
MERCURY COMPOUND, SOLID, N.O.S.
Mercury compound, solid, n.o.s.
14.3
Transport hazard class(es)
14.4
14.5
14.6
15.
ADR/RID: 6.1
Packaging group
ADR/RID: II
Environmental hazards
ADR/RID: no
Special precautions for users
no data available
REGULATORY INFORMATION
IMDG: 6.1
IMDG: II
IMDG Marine pollutant: yes
IATA: 6.1
IATA: II
IATA: no
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.1
15.2
16.
Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
Chemical Safety Assessment
no data available
OTHER INFORMATION
Further information
The above information is believed to be correct but does not purport to be all inclusive and
shall be used only as a guide. The information this document is based on the resent state
of our knowledge and is applicable to the product with regard to appropriate safety precautions.
It does not represent any guarantee of the properties of the product. Lookchem shall not be
held liable for any damage resulting from handling or from contact with the above product.
See reverse side of invoice or packing slip for additional terms and conditions of sale.
;

Recommended suppliers

Ality Chemical Corporation

China (Mainland) Assessed Supplier

Factory Supply Mercury diiodate

  • Assay:99.9%
  • Appearance:Refer to COA
  • Package:drum
  • Storage:keep in cool and dry place
  • Transportation:by sea or by air
  • Application:Intermediates and materials
Contact Supplier

Dayang Chem (Hangzhou) Co.,Ltd.

China (Mainland) Assessed Supplier

Mercury diiodate

  • Assay:98%Min
  • Appearance:detailed in specifications
  • Package:according to the clients requirement
  • Storage:Store in dry, dark and ventilated place.
  • Transportation:by air or by ocean shipping
  • Application:An important raw material and intermediate used in Organic Synthesis, Pharmaceuticals
Contact Supplier

Zibo Hangyu Biotechnology Development Co., Ltd

China (Mainland) Assessed Supplier

Mercuric iodate

  • Assay:99%
  • Appearance:
  • Package:according to customer requirements
  • Storage:
  • Transportation:By Sea/Air/Courier
  • Application:It is an important raw material.
Contact Supplier

weifang yangxu group co.,ltd

China (Mainland) Assessed Supplier

Mercuric iodate

  • Assay:99.9,
  • Appearance:
  • Package:box or opp package
  • Storage:cool drum
  • Transportation:air or sea
  • Application:Mercuric iodate
Contact Supplier

Bluecrystal chem-union

China (Mainland) Assessed Supplier

Mercuric iodate

  • Assay:Grade A,
  • Appearance:white powder
  • Package:drum or based on customers' requirement
  • Storage:normal temperature storage
  • Transportation:by sea, by air
  • Application:We have different specifications for different applications
Contact Supplier

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View