Phenol, polymer with formaldehyde

Material Safety Data Sheet
Flexsil Coating Resin
AMETEK
Specialty Chemical Products Division
Prepared 2/06
Revision 2 Section 1 --- Chemical Product and Company Identification

Trade Name: Flexsil Coating Resin

Manufacturer: AMETEK Chemical Products Division
42 Mountain Avenue
Nesquehoning, PA 18240
Emergency Telephone No.: Chemtrec (800) 424-9300

Section 2 --- Composition/Information on Ingredients

Ingredients CAS N0. % Comp. OSHA PEL ACGIH TLV

Amorphous Silica 7631-86-9 92-98 20 ppm* None
Phenol-Formaldehyde 9003-35-4 15-20** None None
Phenol (free) 108-95-2 Unknown 5 ppm 5 ppm
Formaldehyde (free) 50-00-0 Unknown 0.75 ppm*** None
Ethyl Alcohol 64-17-5 Proprietary 1000 ppm 1000 ppm
Methyl Isobutyl Ketone 108-10-1 2.4 100 ppm 50 ppm
Aliphatic Hydrocarbons None 0.50 None None

* OSHA PEL Table Z-3: Millions of particles per cubic foot of air.
** % of actual coating as a % of the base material.
***See 29 CFR 1910.1048.

Section 3 --- Hazard Information


Appearance and Odor: Reddish brown low viscosity liquid with characteristic alcohol odor.
HMIS Rating: No hazard rating is available for this product.
Primary Entry Routes: Skin contact, inhalation, ingestion and eye contact

Effects of Overexposure:
Inhalation: Vapors may be irritating to the respiratory tract.
Eye: Vapors may be irritating to the eyes.
Skin: May be irritating to the skin and repeated contact may cause dermatitis in sensitive individuals.
Ingestion: May cause temporary irritation of the digestive tract. Phenol (free) is highly toxic by ingestion.

Carcinogenicity:
OSHA carcinogens: Formaldehyde gas
IARC Class 1 (carcinogenic to humans): Formaldehyde gas
IARC Class 3 (possibly carcinogenic to humans): Phenol and amorphous silica
NTP 2 (reasonably anticipated to be a carcinogen): Formaldehyde gas
2/06 AMETEK ?CFlexsil Coating Resin

Section 4 --- First Aid Measures

Inhalation: Move the person to fresh air and support breathing as required. If symptoms (wheezing, coughing,
shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the
victim to a hospital for treatment.
Eye Contact: First check the victim for contact lenses and remove if present. Lift eyelids and flush immediately with
flooding amounts of water for at least 15 minutes. Do not allow the victim to rub his/her eyes or keep them shut.
Consult a physician or ophthalmologist if all material cannot be removed or if there is continuing irritation.
Skin Contact: Remove clothing around affected area. Rinse away loose material and wash affected area with soap
and water. If there is a severe skin reaction or reddened or blistered skin, consult a physician and be prepared to
transport the victim to a hospital for treatment.
Ingestion: Never give anything by mouth to an unconscious or convulsing person. Contact a poison control center
with information from this MSDS and the Technical Data Sheet on the composition of the material ingested. Unless
the poison control center advises otherwise, give the person one or two glasses of water, then induce vomiting. After
first aid have the person see a physician for follow up care.

Section 5 --- Fire Fighting Measures

Flash Point: 60??F, ASTM Method, D 93 (PM CC)
Autoignition Temperature: None reported
Lower Explosive Limit: 3.3% (v) (ethyl alcohol)
Upper Explosive Limit: 19.9 (v) (ethyl alcohol)
Extinguishing Media: Apply Alcohol-type or all purpose-type foam for large fires. Use carbon
dioxide or dry chemical for small fires.
Unusual Fire or Explosion Hazards: During a fire, free phenol and free formaldehyde may be released as well as
their combustion products, carbon monoxide and/or carbon dioxide. Vapors form from this product and may travel or
be moved by air currents and ignited by pilots lights, other flames, smoking , sparks, heaters, electrical equipment,
static discharges or other ignition sources at locations distant from product handling point. Vapors from this material
may settle in low or confined areas or travel a long distance to ignition source and flash back explosively. Static
ignition hazard can result from handling and use. Electrically bond and ground all containers, personnel and
equipment before transfer or use of material. Use proper bonding and grounding during product transfer or use of
material. Use proper bonding and grounding product transfer as described in National Fire Protection Document
NFPA77.
Fire Fighting: Wear a self-contained breathing apparatus (SCBA) with full facepiece operated in the pressure
demand or positive pressure mode. Do not allow runoff from fire fighting to enter roadways or sewers. Material may
dry out and present additional fire/explosion hazards.

Section 6 --- Accidental Release Measures
Wear appropriate protective clothing and respiratory protection for the situation. Cover small spills with sand or other

Cover small spills with non-combustible absorbent. Do not allow spilled material to enter waterway as phenolic resin
may be leached out. Dispose of all waste materials in accordance with all applicable federal, state, and local
environmental regulations



Section 7 --- Handling and Storage

Handling: Use local exhaust ventilation to avoid breathing in vapors. Avoid skin and eye contact - an eyewash
station should be readily available to areas of use. Use safety glasses with sideshields and impervious gloves when
handling this material. Keep away from heat, sparks and open flames.
Storage: Store in closed containers, preferably at 35??F, to maintain maximum shelf life. Protect containers from
physical damage. Area should be well ventilated to minimize vapor exposure.
2/06 AMETEK ?CFlexsil Coating Resin

Section 8 --- Exposure Controls and Personal Protection

Engineering Control and Ventilation:
Provide local exhaust when possible, and general ventilation as necessary, to keep airborne concentrations below
exposure limits and as low as possible. When material is used at elevated temperatures, adequate ventilation must be
provided.
Respiratory Protection: Use an NIOSH approved full face-piece respiratory protection equipment where air
contaminants exceed acceptable criteria. Use self contained breathing apparatus where extremely high vapor
concentrations are presents.
Eye Protection: Safety glasses with side shields or chemical splash goggles must be worn to prevent eye contact. A
good safety practice is to have an eyewash station readily available near the work area.
Skin Protection: Use impervious gloves such as neoprene, nitrile, or rubber for hand protection. Chemical resistant
apron or coveralls is also recommended. These should be worn one day only if exposed to particulates, and washed
before reuse.

Section 9 --- Physical and Chemical Properties
Physical State: Reddish-Brown
Appearance/Odor: Characteristic alcohol odor
Solubility: Negligible
Specific Gravity (H2O=1): 0.95

Section 10 --- Stability and Reactivity

Stability: Product is stable at normal temperature and storage conditions, but will polymerize at high temperatures
with some evolution of heat.
Chemical Incompatibilities: Strong mineral acids such as sulfuric or hydrochloric acid, oxidizers.
Conditions to Avoid: Contamination from other materials.
Hazardous Polymerization: Hazardous polymerization will not occur under normal conditions.
Hazardous Decomposition Products: Under fire conditions polymers decompose. Thermal decomposition of any
small amount of binder may produce carbon monoxide and carbon dioxide.


Section 11 --- Toxicological Information

Phenol:
Acute inhalation, mouse - LC50 = 177 mg/m3 Ethyl Alcohol:
Acute inhalation, mouse ?? LC50 = 39 gm/m3/4 hour
Acute dermal, rabbit - LD50 = 630 mg/kg
Acute intraperitoneal, rabbit ?? LD50 = 963 mg/kg
Formaldehyde (free):
Acute inhalation, cat - LCLO = 400 mg/m3/2 hours Methyl Isobutyl Ketone:
Acute inhalation, mouse ?? LC50 = 23,300 mg/m3
Acute oral, rat ?? LD50 = 500 mg/kg
Acute oral, guinea pig ?? LC50 = 1,600 mg/kg
Amorphous Silica:
Acute oral, rat ?? LD50 = 3,160 mg/kg
Acute intravenous, rat ?? LD50 = 15 mg/kg



Section 12 --- Ecological Information

Phenol-formaldehyde polymers have a very low rate of biodegradation. Bio-accumulation is expected to be
minimal. Unreacted phenolic monomer may be leached into ground water even after normal curing has occurred.
2/06 AMETEK ?CFlexsil Coating Resin


Section 13 --- Disposal Considerations

Disposal of all waste including containers in accordance with applicable, federal, State and local Environmental
regulations.

Section 14 --- Transport Information

DOT Proper Shipping Name: Resin solution, flammable
Technical Name: Phenolic resin, solvated
DOT Hazardous Class: 3
DOT UN/NA Number: UN 1866
Packaging Group: PG III
Emergency Response Guide Number: None


Section 15 --- Regulatory Information

CERCLA CERCLA CWA CAA SARA SARA
Hazardous Reportable NPDES Section Toxic Extremely
Component Substance Quantity Discharge 112 Chemical Hazardous
(Section 102) (Lbs.) (Section (40 CFR Substance
307(a) 372) (40 CF 355)

7631-86-9 --- --- --- --- --- ---
9003-35-4 --- --- --- --- --- ---
108-95-2 X 1,000 X X X X
50-00-0 X 100 X X X X
64-17-5 --- --- --- --- --- ---
108-10-1 X 5,000 --- X X ---
Aliphatic
Hyrocarbons --- --- --- --- --- ---

Components listed as OSHA air contaminants are found in Section 2 of this MSDS.

Section 16 --- Other Information

The following chemicals are subject to the reporting requirements of Section 313 of the Emergency Planning and
Community Right-to-Know Act of 1986 and of 40 CFR 372: Phenol, formaldehyde and methyl isobutyl ketone.

THE ABOVE INFORMATION IS BELIEVED TO BE ACURATE BASED ON THE MOST CURRENT DATA
AVAILABLE. AMETEK MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO
SUCH INFORMATION, AND ASSUMES NO LIABILITY RESULTING FROM ITS USE. USERS ARE
ADVISED TO CONDUCT THEIR OWN TEST TO DETERMINE THE SAFETY AND SUITABILITY OF EACH
PRODUCT OR PRODUCT COMBINATION FOR THEIR OWN PURPOSES. AMETEK SHALL NOT BE
LIABLE FOR ANY CLAIMS, LOSSES OR DAMAGES OF ANY THIRD PARTY OR FOR LOST PROFITS O INCIDENTAL OR CONSEQUENTAL DAMAGES.

Prepared 2/06, Revision 2

;

Recommended suppliers

HENAN NEW BLUE CHEMICAL CO.,LTD

China (Mainland) Assessed Supplier

Newblue-CHEM PHENOL-FORMALDEHYDE RESIN

  • Assay:99%
  • Appearance:white powder
  • Package:200KG
  • Storage:room temperature
  • Transportation:By sea , by air or express
  • Application:Industrial Grade
Contact Supplier

Chongqing Changfeng Chemical Co., Ltd.

China (Mainland) Assessed Supplier

Phenolic resin 2402

  • Assay:high purity
  • Appearance:light yellow colour solid
  • Package:25kg bag
  • Storage:Kept in dry and well-ventilated place,avoid humidity,direct sun shine,away from fire.
  • Transportation:by truck, by sea.
  • Application:
Contact Supplier

Dayang Chem (Hangzhou) Co.,Ltd.

China (Mainland) Assessed Supplier

Phenol-formaldehyde resin Manufacturer/High quality/Best price/In stock

  • Assay:Industrial Grade,
  • Appearance:Black, Brown
  • Package:according to the clients requirement
  • Storage:Store in dry, dark and ventilated place.
  • Transportation:by sea or by air
  • Application:It is an important raw material and intermediate used in Organic Synthesis, Pharmaceuticals, Agrochemicals and Dyestuff.
Contact Supplier

Hebei yanxi chemical co.,LTD.

China (Mainland) Assessed Supplier

PHENOL-FORMALDEHYDE RESIN

  • Assay:1,
  • Appearance:light yellow granule
  • Package:25kg\bucket
  • Storage:Ventilated, dry and cool
  • Transportation:shipping
  • Application:intermediates
Contact Supplier

Henan Allgreen Chemical Co.,Ltd

China (Mainland) Assessed Supplier

PHENOL-FORMALDEHYDE RESIN

  • Assay:98%
  • Appearance:White or off-white Solid
  • Package:According to the demand of customer
  • Storage:Sealed, dry, microtherm , avoid light and smell.
  • Transportation:by air or by sea
  • Application:Organic synthesis
Contact Supplier

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View