1,2,4-Benzenetricarboxylicacid, mixed branched tridecyl and isodecyl esters

??
LUBRIPLATE
MATERIAL SAFETY DATA SHEET
Section 1
PRODUCT NAME OR NUMBER FORMULA
LUBRIPLATE Synac 220 Synthetic Ester Base Oil and Additives
GENERIC/CHEMICAL NAME: NSF Registration No:
Synthetic Lubricating Oil N/A
Manufacturer's Name Emergency Telephone Number
Fiske Brothers Refining Co., d/b/a LUBRIPLATE Lubricants Co. 1-800-255-3924 - CHEM-TEL (24 hour)

Address Telephone Number for Information
1500 Oakdale Ave., Toledo, Ohio 43605 - 129 Lockwood St., Newark, NJ 07105 419-691-2491 - Toledo Office

Section 2 ?? Composition/Information on Ingredients
Non-Hazardous Ingredients CAS# Percentage
Synthetic Ester Oils 70225-05-7 95 - 100%
Additive 1330-78-5 0 - 3%
Additive 597-82-0 0 - 3%
Hazardous Material Identification System (HMIS): Health - 1, Flammability - 1, Reactivity ?? 0

Not a Controlled Product under (WHMIS) - Canada Special Protection: See Section 9

Section 3 - Health Hazard Data
5 mg/m3 for oil mist in air. OSHA Regulation 29 CFR 1910.1000
Threshold Limit Value
Effects of Overexposure Prolonged or repeated skin contact may cause skin irritation. Product contacting the eyes may cause eye irritation.
Human health risks vary from person to person. As a precaution, exposure to liquids, vapors, mists and fumes should be minimized. This
product has a low order of acute oral toxicity, but minute amounts aspirated into the lungs during ingestion may cause mild to severe
pulmonary injury.
Carcinogenicity: NTP? No IARC Monographs? No OSHA Regulated? No

Section 4 - Emergency and First Aid Procedures
EYE CONTACT: Flush with clear water for 15 minutes or until irritation subsides. If irritation persists, consult a physician.

SKIN CONTACT: Remove any contaminated clothing and wash with soap and warm water. If injected by high pressure under skin,
regardless of the appearance or its size, contact a physician IMMEDIATELY. Delay may cause loss of affected part of the body.

INHALATION: Vapor pressure is very low and inhalation at room temperature is not a problem. If overcome by vapor from hot product,
immediately remove from exposure and call a physician.

INGESTION: If ingested, call a physician immediately. Do not induce vomiting.

Section 5 - Fire and Explosion Hazard Data

COC - > 500oF
Flash Point (Method Used) Flammable Limits LEL N.D UEL N.
Extinguishing Media Foam, Dry Chemical, Carbon Dioxide or Water Spray (Fog)

Special Fire Fighting Procedures Cool exposed containers with water. Use air-supplied breathing equipment for
enclosed or confined spaces.

Unusual Fire and Explosion Hazards Do not store or mix with strong oxidants. Empty containers retain residue.
Do not cut, drill, grind, or weld, as they may explode.
PRODUCT NAME OR NUMBER - LUBRIPLATE Synac 220
Section 6 - Physical/Chemical Characteristics

Boiling Point N/A Specific Gravity (H 2O = 1) 0.99

Vapor Pressure (mm Hg.) N/A Melting Point Liquid

Vapor Density (AIR = 1) N/A Evaporation Rate N/A
(Butyl Acetate = 1)
Solubility in Water Negligible

Appearance and Odor Clear, oily liquid with mild odor.

Section 7 - Reactivity Data

Stability Unstable Conditions to Avoid High Temperatures
Stable X

Incompatibility (Materials to Avoid) Avoid contact with strong acids or strong bases.

Hazardous Decomposition or Byproducts CO, CO2.

Hazardous Polymerization May Occur Conditions to Avoid N/A
Will Not Occur X

Section 8 - Spill or Leak Procedures

Steps to be taken in case material is released or spilled
Recover liquid, wash remainder with suitable petroleum solvent or add absorbent. Keep petroleum products out of sewers and water courses.
Advise authorities if product has entered or may enter sewers and water courses.

Waste disposal method
Assure conformity with applicable disposal regulations. Dispose of absorbed material at an approved waste disposal facility or site.


Section 9 - Special Protection Information

Respiratory Protection (Specify type) Use NIOSH approved organic vapor cartridges respirator.

Ventilation Local Exhaust Used to capture fumes and vapors Special N/A
Mechanical (General) Other N/A

Protective Gloves Use oil-resistant gloves, if needed. Eye Protection If chance of eye contact, wear goggles.

Other Protective Equipment Use oil-resistant apron, if needed.

Section 10 - Special Precautions

Precautions to be taken in handling and storing
Keep containers closed when not in use. Do not handle or store near heat, sparks, flame, or strong oxidants.

Other Precautions
Avoid breathing oil mist. Remove oil-soaked clothing and launder before reuse. Cleanse skin thoroughly after contact.


The above information is furnished without warranty, expressed or implied, except that it is accurate to the best knowledge of Fiske
Brothers Refining Co., d/b/a LUBRIPLATE Lubricants Co. The data on these sheets relates only to the specific material designated
herein. Fiske Brothers Refining Co., d/b/a LUBRIPLATE Lubricants Co. assumes no legal responsibility for use or reliance upon
this data.



Date Prepared: October 1, 2007 Prepared by: James R. Kontak

;

Recommended suppliers

Ality Chemical Corporation

China (Mainland) Assessed Supplier

Factory Supply 1,2,4-Benzenetricarboxylic acid, mixed branched tridecyl and isodecyl esters

  • Assay:99.9%
  • Appearance:Refer to COA
  • Package:drum
  • Storage:keep in cool and dry place
  • Transportation:by sea or by air
  • Application:Intermediates and materials
Contact Supplier

Lonwin Chemical Group Limited

China (Mainland) Assessed Supplier

Factory supply TRIDECYLTRIMELLITATE

  • Assay:Assay,
  • Appearance:white or almost white crystalline powder
  • Package:Pack & Store:25kg cardboard barrels lined with plastic bags; or otherwise customized
  • Storage:In cool ,dry place
  • Transportation:Preservce in well-closed containers, prptected from light,
  • Application:USP34 Or EP STANDERUsed as Antibiotic and Antimicrobial Agents
Contact Supplier

Henan Tianfu Chemical Co., Ltd.

China (Mainland) Assessed Supplier

TIANFU-CHEM TRIDECYLTRIMELLITATE

  • Assay:99%
  • Appearance:white powder
  • Package:200KG
  • Storage:room temperature
  • Transportation:By sea , by air or express
  • Application:Industrial Grade
Contact Supplier

TAIZHOU ZHENYU BIOTECHNOLOGY CO., LTD

China (Mainland) Assessed Supplier

TRIDECYLTRIMELLITATE

  • Assay:Pharmaceutocal Grad ,
  • Appearance:Detailed in specifications
  • Package:According to customer
  • Storage:Store in dry, dark and ventilated place
  • Transportation:By air or by sea
  • Application:An important raw material and intermediate used in organic Synthesis, Pharmaceuticals
Contact Supplier

Bluecrystal chem-union

China (Mainland) Assessed Supplier

1,2,4-Benzenetricarboxylicacid, mixed branched tridecyl and isodecyl esters

  • Assay:Grade A,
  • Appearance:white powder
  • Package:drum or based on customers' requirement
  • Storage:normal temperature storage
  • Transportation:by sea, by air
  • Application:We have different specifications for different applications
Contact Supplier

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View