Palladium,bis(benzonitrile)dichloro-

1.
1.1
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product identifiers
Product name
Product Number
Brand
CAS-No.
:
:
:
:
Bis(benzonitrile)palladium(II) chloride
223689
14220-64-5
1.2
Relevant identified uses of the substance or mixture and uses advised against
Identified uses
:
Laboratory chemicals, Manufacture of substances
2.
2.1
2.2
2.3
3.
3.1
HAZARDS IDENTIFICATION
Classification of the substance or mixture
Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.
Label elements
The product does not need to be labelled in accordance with EC directives or respective national laws.
Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS
Substances
Synonyms
Formula
Molecular Weight
- 223689
:
:
:
Palladium(II) chloride bis(benzonitrile) complex
Benzonitrile, palladium complex
Bis(benzonitrile)dichloropalladium(II)
Bis(benzonitrile)palladium(II) chloride
Bis(phenylnitrile)dichloropalladium
Dibenzonitrilepalladium dichloride
Dichlorobis(benzonitrile)palladium
Dichlorobis(benzonitrile)palladium(II)
Dichlorobis(phenyl cyanide)palladium
Palladium dichloride bis(benzonitrile)
C14H10Cl2N2Pd
383,57 g/mol
4.
4.1
4.2
4.3
5.
5.1
5.2
5.3
5.4
6.
6.1
6.2
6.3
6.4
7.
7.1
7.2
7.3
FIRST AID MEASURES
Description of first aid measures
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration.
In case of skin contact
Wash off with soap and plenty of water.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water.
Most important symptoms and effects, both acute and delayed
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
Indication of any immediate medical attention and special treatment needed
no data available
FIREFIGHTING MEASURES
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Carbon oxides, nitrogen oxides (NOx), Hydrogen chloride gas
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available
ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Avoid dust formation. Avoid breathing vapors, mist or gas.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up
Sweep up and shovel. Keep in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE
Precautions for safe handling
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire
protection.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Specific end uses
no data available
- 223689
8.
8.1
8.2
9.
9.1
EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
General industrial hygiene practice.
Personal protective equipment
Eye/face protection
Use equipment for eye protection tested and approved under appropriate government standards
such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
the standard EN 374 derived from it.
Body Protection
Choose body protection in relation to its type, to the concentration and amount of dangerous
substances, and to the specific work-place., The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Respiratory protection is not required. Where protection from nuisance levels of dusts are desired,
use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and
approved under appropriate government standards such as NIOSH (US) or CEN (EU).
PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
a)
b)
c)
d)
e)
f)
g)
h)
Appearance
Odour
Odour Threshold
pH
Melting point/freezing
point
Initial boiling point and
boiling range
Flash point
Evaporation rate
Form: solid
no data available
no data available
no data available
Melting point/range: 131 °C - lit.
no data available
no data available
no data available
i)
Flammability (solid, gas) no data available
j)
k)
l)
Upper/lower
flammability or
explosive limits
Vapour pressure
Vapour density
no data available
no data available
no data available
m) Relative density
no data available
n)
o)
Water solubility
Partition coefficient: n-
no data available
no data available
- 223689
octanol/water
p)
q)
r)
s)
t)
Autoignition
temperature
Decomposition
temperature
Viscosity
Explosive properties
Oxidizing properties
no data available
no data available
no data available
no data available
no data available
9.2
10.
10.1
10.2
10.3
10.4
10.5
10.6
11.
11.1
Other safety information
no data available
STABILITY AND REACTIVITY
Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - no data available
TOXICOLOGICAL INFORMATION
Information on toxicological effects
Acute toxicity
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC:
No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
- 223689
Potential health effects
Inhalation
Ingestion
Skin
Eyes
May be harmful if inhaled. May cause respiratory tract irritation.
May be harmful if swallowed.
May be harmful if absorbed through skin. May cause skin irritation.
May cause eye irritation.
Signs and Symptoms of Exposure
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
Additional Information
RTECS: Not available
12.
12.1
12.2
12.3
12.4
12.5
12.6
13.
13.1
14.
14.1
ECOLOGICAL INFORMATION
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
no data available
Other adverse effects
no data available
DISPOSAL CONSIDERATIONS
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging
Dispose of as unused product.
TRANSPORT INFORMATION
UN number
14.2
14.3
14.4
14.5
14.6
15.
ADR/RID: -
UN proper shipping name
ADR/RID:
Not dangerous goods
IMDG:
Not dangerous goods
IATA:
Not dangerous goods
Transport hazard class(es)
ADR/RID: -
Packaging group
ADR/RID: -
Environmental hazards
ADR/RID: no
Special precautions for user
no data available
REGULATORY INFORMATION
IMDG: -
IMDG: -
IMDG: -
IMDG Marine pollutant: no
IATA: -
IATA: -
IATA: -
IATA: no
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
- 223689
15.1
15.2
16.
Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
Chemical Safety Assessment
no data available
OTHER INFORMATION
Further information
The above information is believed to be correct but does not purport to be all inclusive and
shall be used only as a guide. The information this document is based on the resent state
of our knowledge and is applicable to the product with regard to appropriate safety precautions.
It does not represent any guarantee of the properties of the product. Lookchem shall not be
held liable for any damage resulting from handling or from contact with the above product.
See reverse side of invoice or packing slip for additional terms and conditions of sale.

;

Recommended suppliers

Simagchem Corporation

China (Mainland) Assessed Supplier

High quality Palladium(Ii) Chloro-Bis(Benzonitrile) supplier in China

  • Assay:99%
  • Appearance:white-off solid or colorless liquid ( referto COA)
  • Package:25kgs/fiber drum or 200kgs/UN drum
  • Storage:in a cool and dry place
  • Transportation:by sea or by air
  • Application:organic intermediates
Contact Supplier

Hebei yanxi chemical co.,LTD.

China (Mainland) Assessed Supplier

Bis(benzonitrile)palladium chloride

  • Assay:1,
  • Appearance:yellow powder
  • Package:25kg\bucket
  • Storage:Ventilated, dry and cool
  • Transportation:shipping
  • Application:TNJ pharmaceuticals
Contact Supplier

HANGZHOU TIANYE CHEMICALS CO., LTD.

China (Mainland) Assessed Supplier

Dichlorobis(benzonitrile)palladium(II)

  • Assay:98%
  • Appearance:Orange to brown Crystalline Powder
  • Package:drum
  • Storage:Inert atmosphere,2-8°
  • Transportation:According to your request
  • Application:Noble metal catalyst
Contact Supplier

Amadis Chemical Co., Ltd.

China (Mainland) Assessed Supplier

Amadis Chemical offer CAS#14220-64-5;CAT#A807865

  • Assay:97%
  • Appearance:Powder or liquid
  • Package:According to customer
  • Storage:Store in a tightly closed container, in a cool and dry place.
  • Transportation:Fedex,DHL,TNT,BY SEA and BY AIR
  • Application:Medicinal Chemistry Biomedicine Pharmaceutical intermediates Chemistry experiment Biological experiments Chemical reagent For R&D use only.
Contact Supplier

Bis(benzonitrile)palladium chloride

  • Assay:99%
  • Appearance:Yellow crystalline powder
  • Package:glass bottle, PTFE bottle, aluminium foil bag, cardborad drum
  • Storage:seal, dry
  • Transportation:By air by sea or courier
  • Application:pharmaceutical and research
Contact Supplier

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View