Add time:08/11/2019 Source:sciencedirect.com
Titanium-zirconium-molybdenum (TZM) alloy was fabricated by using powder metallurgy and rolling techniques. Electrochemical corrosion behavior of the alloy was studied quantitatively using potentiodynamic polarization and scanning electron microscope. Effect of different chloride ions concentrations on corrosion resistance and electrochemical corrosion mechanism on TZM alloy was investigated. Results show that pitting corrosion and intergranular corrosion of TZM alloy mainly occurs in sodium chloride solution. Corrosion generates firstly in the form of pitting corrosion around second phase particles and increases with corrosive media Cl− concentration increasing, and then the intergranular corrosion occurs along grain boundaries and defects. Cl− corrosion can effectively destroy the passive film formed on the sample surface. As the Cl− concentration of corrosive media increases, the corrosion rate of TZM alloy increases until 1.0 mol/L and then decreases. TZM alloy exhibits good corrosion resistance when the concentration of Cl− in corrosive media is 0.5 mol/L or 1.5 mol/L.
We also recommend Trading Suppliers and Manufacturers of MOLYBDENUM CHLORIDE (cas 13478-17-6). Pls Click Website Link as below: cas 13478-17-6 suppliers
About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia
Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog
©2008 LookChem.com,License: ICP
NO.:Zhejiang16009103
complaints:service@lookchem.com Desktop View