Encyclopedia

  • Improvements of COBRA-TF on the effect of flow blockage during a LB LOCA with consideration of fuel relocation phenomenon
  • Add time:08/17/2019         Source:sciencedirect.com

    Coolability of the partially blocked core in a large break loss-of-coolant accident (LB LOCA) is one of the most important thermal-hydraulic concerns for nuclear reactor safety analysis. During blowdown phase and early stage of reflooding phase in the LB LOCA, the prevailing wall-to-vapor convective heat transfer plays an important role on the decay heat removal process. Experiments on single-phase convective heat transfer to vapor were conducted in 5 × 5 heater rod bundles containing 3 × 3 ballooned rods of 90% flow blockage ratio with consideration of fuel relocation phenomenon. The obtained experimental data were used to assess the single-phase heat transfer enhancement models of the COBRA-TF code. The assessment results showed underprediction of local heat transfer downstream of the flow blockage. Therefore, a new correlation has been proposed to improve the prediction capability of the conventional models by more accurately describing the flow blockage effect. The new correlation predicted the local heat transfer satisfactorily within a 20% discrepancy of the experimental data for various kinds of flow blockage configurations.

    We also recommend Trading Suppliers and Manufacturers of TF-A (cas 134965-85-8). Pls Click Website Link as below: cas 134965-85-8 suppliers


    Prev:Performance analysis of a graded winding pack design for the EU DEMO TF coil in normal and off-normal conditions
    Next: Structure–activity relationship of Phosmidosine (cas 134966-01-1): importance of the 7,8-dihydro-8-oxoadenosine residue for antitumor activity)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View