This paper evaluates the immunopurification behavior of a plantibody HBsAg specific plantibody coupled to SEPHAROSE CL-4B (cas 61970-08-9) at different ligand densities. Results show no significant differences in the adsorption and elution capacities, and rHBsAg recovery of immunosorbents at 3.43, 4.45, and 5.31 mg/mL of ligand densities compared to its mouse-derived mAb counterpart consistently used in the rHBsAg purification process. Therefore, plantibody ligand densities higher than 3.43 mg/mL do not improve the immunopurification behavior of this immunosorbent, but increase the antibody consumption and the Hepatitis B vaccine cost. Immunosorbent of 2.23 mg/mL of ligand density demonstrated a poor performance. The IgG leached detectable level never exceeded the approved limit (3 ng IgG/μg rHBsAg). Values close to this limit were only observed at the ligand density of 5.31 and 2.27 mg/mL. In the case of the ligand density of 2.23 mg/mL the IgG leached value was high (2.90 ng IgG/μg rHBsAg) due to a low level of eluted antigen. In conclusion, it supports feasibility of using this plantibody at 3.43 mg/mL of ligand density for large-scale immunopurification of rHBsAg for human use, avoiding the biosafety and ethical concerns of the massive use of animals for this purpose.