Encyclopedia

  • Regular ArticleError Analysis for Quantification of [11C]FLB 457 (cas 107188-66-9) Binding to Extrastriatal D2 Dopamine Receptors in the Human Brain
  • Add time:08/19/2019         Source:sciencedirect.com

    To estimate receptor binding of ligand by positron emission tomography (PET) without an arterial input function, several quantitative approaches based on the use of a reference region have been proposed. We compared three approaches for quantifying extrastriatal D2 dopamine receptors using [11C]FLB 457. The PET measurements were performed on seven healthy men. Binding potential (BP) of [11C]FLB 457 was calculated by the reference tissue model method, transient equilibrium method, and late time method. The reference tissue model describes the time-activity curve in a brain region in terms of that in the reference region, assuming that the levels of nondisplaceable radioligand binding in both regions are the same. The transient equilibrium theoretically occurs when the derivative for specific binding is zero. With the late time method, BP is calculated by integrating a late part of the time-activity curve. BP values obtained by all methods were in good agreement with those obtained by the kinetic approach, and the highest coefficient of correlation was observed in the reference tissue model method. In the simulation study, the error of BP calculated by the reference tissue model method was smallest. Moreover, the effect of the difference in the influx rate constant K1 between the brain and the reference regions on BP was nearly avoided as theoretically predicted. We concluded that the reference tissue model method is most suitable for calculating BP of extrastriatal D2 dopamine receptors with [11C]FLB 457.

    We also recommend Trading Suppliers and Manufacturers of FLB 457 (cas 107188-66-9). Pls Click Website Link as below: cas 107188-66-9 suppliers


    Prev:Regular ArticlePET Mapping of Extrastriatal D2-like Dopamine Receptors in the Human Brain Using an Anatomic Standardization Technique and [11C]FLB 457 (cas 107188-66-9)
    Next: A comparison of recent parametric neuroreceptor mapping approaches based on measurements with the high affinity PET radioligands [11C]FLB 457 (cas 107188-66-9) and [11C]WAY 100635)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View