Add time:08/13/2019 Source:sciencedirect.com
A sensitive and selective high-performance liquid chromatographic method is described for the determination of a novel calcium antagonist, (+)-(R)-3,4-dihydro-2-[5-methoxy-2-[3-[N-methyl-N-[2-[(3,4-methylenedioxy)phenoxy]ethyl]amino]propoxy]phenyl]-4-methyl-3-oxo-2H-1,4-benzothiazine hydrogen fumarate (sesamodil (cas 116476-14-3) fumarate; JAN, SD-3211, I), and its N-desmethylated metabolite (II) in plasma. Compounds I and II and an internal standard were isolated from plasma by solid-phase and liquid-liquid extraction. The extract was chromatographed on a reversed-phase C18 column, and the compounds of interest were detected by dual coulometric electrodes operated in an oxidative screen mode. The limit of determination for both I and II was at least 0.4 ng/ml in plasma. The utility of the assay was demonstrated by determining plasma levels of I and II in five dogs administered an oral dose of 60 mg of the drug.
We also recommend Trading Suppliers and Manufacturers of sesamodil (cas 116476-14-3). Pls Click Website Link as below: cas 116476-14-3 suppliers