Encyclopedia

  • Influence of operating parameters during electrocoagulation of sodium chloride and sodium bicarbonate solutions using aluminium electrodes
  • Add time:08/22/2019         Source:sciencedirect.com

    Sodium salts are common in solutions used in electrocoagulation (EC) studies especially in relation to treatment of produced water. However, the influence of sodium salts upon electrocoagulation operating parameters is not well understood. Therefore, a multi-electrode electrocoagulation cell with aluminium electrodes was used to investigate the impact of polarity reversal period, electrode history, sodium chloride/sodium bicarbonate concentration, floc characteristics and starting solution pH. Effluent pH exhibited oscillating behaviour which related to electrode passivation, with cleaner electrodes raising pH and electrodes with oxide coatings decreasing pH due to variations in anode dissolution and oxidation of water. Polarity reversal could lower cell resistance by de-passivating the electrode surface with a 3 min reversal time recommended. However, electricity (2.56 kWh/kL) and electrode consumption (0.448 g/min) were enhanced. Imaging revealed that the presence of sodium chloride induced extensive pitting corrosion of the aluminium electrodes, whereas pitting was only observed with high concentrations of sodium bicarbonate. Sodium bicarbonate suppressed pH oscillation due to electrode passivation. The amount of electrode consumed was greater than predicted from Faraday’s Law and as such non-electrochemical processes occurred. The wear of electrodes was uneven with those with highest load at the EC cell extremities wearing the fastest. Floc settling rates were relatively slow and not significantly impacted by salt concentration. The settled volume after 1 h was still greater than 60% of the initial volume, which may cause issues with floc separation. Residual aluminium ions in the effluent were present which may impact downstream membrane performance.

    We also recommend Trading Suppliers and Manufacturers of Aluminium(II)chloride (cas 16603-84-2). Pls Click Website Link as below: cas 16603-84-2 suppliers


    Prev:Formation, extracellular polymeric substances and microbial community of aerobic granules enhanced by microbial flocculant compared with poly-aluminum chloride
    Next: Structural elucidation of supported Rh complexes derived from RhCl(PPh3)3 immobilized on surface-functionalized SBA-15 and their catalytic performance for C-heteroatom (S, O) bond formation)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View