Encyclopedia

  • Vapor pressure measurement of lead and Lead chloride (cas 12612-47-4)s in FeOT–CaO–SiO2–Al2O3 system
  • Add time:08/17/2019         Source:sciencedirect.com

    Vapor pressure of lead and lead chlorides from FeOT–CaO–SiO2–Al2O3 slag system was measured by using Knudsen effusion method. The results suggest that the vapor pressures of lead and lead chlorides increase with increasing temperature. For the slag systems without chlorine, the logarithm of vapor pressure (lnp) shows highly linear dependency on the reciprocal of temperature (1/T), and higher vapor pressure is observed in the condition where more metallic lead vapor is formed. In this case, the vapor pressure of lead increases with increasing slag basicity (w(CaO)/w(SiO2)), increasing FeO content and w(Fe2+)/w(Fe3+) ratio. For the case of slag system with chlorine addition, the total pressures of PbCl2 and PbCl increase with decreasing basicity and FeO content of slag.

    We also recommend Trading Suppliers and Manufacturers of Lead chloride (cas 12612-47-4). Pls Click Website Link as below: cas 12612-47-4 suppliers


    Prev:Full Length ArticleElectrodeposition of lead selenide films from ionic liquids based on choline chloride
    Next: Autophagy plays a protective role in cell death of osteoblasts exposure to Lead chloride (cas 12612-47-4))