Add time:08/25/2019 Source:sciencedirect.com
A simple gas chromatographic method is described for the analysis of 3,3′-dichloro-4,4′-diaminodiphenylmethane (MOCA) in air. MOCA is quantitatively collected on a Gas-Chrom S tube and the solid sorbent is extracted with acetone. An aliquot sample of the extract is introduced directly into the gas chromatograph, using a microsyringe and the sample is chromatographed on a 1-ft., silylated 10% Dexsil column. The peak area of MOCA is measured and related to the concentration via a calibration curve prepared with a constant volume of standards. The chloroanilines associated with MOCA cause no interference; however, interference can be expected from any compounds having a retention time identical to that of MOCA. As little as 0.002 μg of MOCA per μl of acetone can be detected by this method.
We also recommend Trading Suppliers and Manufacturers of 3,3'-DIAMINODIPHENYLMETHANE (cas 19471-12-6). Pls Click Website Link as below: cas 19471-12-6 suppliers