Encyclopedia

  • Simultaneous determination of hemes a, b, and c from pyridine hemochrome (cas 15629-11-5) spectra☆
  • Add time:08/31/2019         Source:sciencedirect.com

    Two procedures for analyzing overlapping optical spectra of mixtures of pyridine hemochrome (cas 15629-11-5)s are described, and extinction coefficients of pyridine hemochromes are provided for use with these methods. In the first procedure, absorbance is measured at a number of wavelengths equal to the number of components to be analyzed. This is the minimum amount of spectral data from which the concentration of each species can be calculated. In the second procedure, absorbance is measured at a number of wavelengths greater than the number of components to be analyzed. This redundancy of information makes it impossible to fit spectra which contain contributions from additional components, unless the spectra of the additional components are equal to linear combinations of the spectra of the species being analyzed. These two procedures are generally applicable to analyses of absolute or difference spectra of mixtures of components obeying Beer's law. The sensitivity to error in the absorbance measurements is only slightly greater than that for measuring a pure component at a single wavelength.

    We also recommend Trading Suppliers and Manufacturers of pyridine hemochrome (cas 15629-11-5). Pls Click Website Link as below: cas 15629-11-5 suppliers


    Prev:The effects of various amendments on the biostimulation of perchlorate reduction in laboratory microcosm and flowthrough soil columns
    Next: [28] Detection, formation, and relebance of hemochromes and hemochromes)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View