Encyclopedia

  • Separation of uranium(VI) and lanthanides by capillary electrophoresis using on-capillary complexation with arsenazo III
  • Add time:09/25/2019         Source:sciencedirect.com

    The viability of the separation of lanthanides and uranium(VI) in the form of strongly absorbing complexes with arsenazo III (AIII) was studied with the aim to increase the sensitivity of absorbance detection in determination of these metals by capillary electrophoresis (CE). Special attention was paid to the complexation equilibria in the background electrolyte (BGE). On-capillary complexation provided better peak shapes for lanthanides compared to pre-column complexation. While the BGE composition had very little effect on the peak shape of the kinetically inert uranium(VI) complex, it played a crucial role in the peak shapes of the kinetically labile lanthanide complexes. Addition of a second ligand competing with the metallochromic ligand AIII for the metal ions was found to be critical to achieve good peak shape. The nature and concentration of the competing complexing ligand added to the BGE, the pH, and the concentration of AIII were found to exert a strong influence on the separation selectivity, peak shapes and the detection sensitivity. Several carboxylic acids were compared as BGE competing ligands and citrate provided best selectivity and peak shapes. A citrate BGE at pH 4.7 and containing 0.1 mM AIII was used for the separation of uranium(VI) (350 000 theoretical plates) and LaIII (63 000 theoretical plates) while, to separate most lanthanides and uranium(VI), a similar BGE with a lower (0.03 mM) AIII concentration was used. Using hydrostatic sampling (100 mm for 10 s) detection limits of 0.35 μM (49 ppb) LaIII and 25 μM (60 ppb) UO2 were obtained. Using on-capillary complexation, sample stacking was retained for injection times of up to at least 100 s (ca. 30-mm sample plug) without loss of peak shapes for lanthanides or recovery for LaIII. When this process was used, the detection limit for LaIII was reduced to about 5 ppb. Optimal properties of metallochromic ligands for separation and detection of metals by CE are discussed.

    We also recommend Trading Suppliers and Manufacturers of ARSENAZO III SODIUM (cas 138608-19-2). Pls Click Website Link as below: cas 138608-19-2 suppliers


    Prev:A novel methodology for evaluation of formation constants of complexes: example of lanthanide–Arsenazo III complexes
    Next: The binding of arsenazo III to cell components)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View