Add time:09/24/2019 Source:sciencedirect.com
A method to produce high purity hydrogen using the corrosion of tin metal in lactic acid solutions is studied. The addition of sodium perchlorate has been also investigated for promoting the tin-lactic acid reaction. The data reveal that the rate of hydrogen production increases with increasing lactic acid concentration. The presence of perchlorate ions in lactic acid solution enhances the active dissolution of tin metal and tends to breakdown the passive film and promoting the hydrogen generation rate. Polarization measurements show that the breakdown potential (Epit) decreases with increase in sodium perchlorate concentration. An increase in temperature accelerates the rate of solubility of passive layer on the tin surface. Moreover, a synergistic effect of sodium perchlorate in combination with increasing the solution temperature is key in promoting the hydrogen generation rate. Results obtained from hydrogen and polarization measurements are in good agreement. These measurements are complemented with SEM, EDX and XRD examinations of the electrode surface.