Encyclopedia

  • Water management in a single cell proton exchange membrane fuel cells with a Serpentine (cas 131-07-7) flow field
  • Add time:09/29/2019         Source:infona.pl

    Gas and water management is the key to achieving good performance from a polymer electrolyte membrane fuel cell (PEMFC) stack. Imbalance between production and evaporation rates can result in either flooding of the electrodes or membrane dehydration, both of which severely limit fuel cell performance. In the present study, a mathematical model was developed to evaluate moisture profiles of hydrogen and air flows in the flow field channels of both the anode and the cathode. For model validation, a single fuel cell was designed with an active area of 200cm 2 . Six humidity sensors were installed in the flow fields of both the anode and the cathode at 457mm, 1266mm and 2532mm from the inlets. The experiment was performed using an Arbin Fuel Cell Test Station. The temperature was varied (25°C, 40°C, 50°C and 60°C), while hydrogen and air velocities were fixed at 3Lmin −1 and 6Lmin −1 , respectively, during the operation of the single cell. The feed relative humidity at the anode was fixed at 1.0, while the feed relative humidity at the cathode was fixed at 0.005 (dry air). All humidity sensor readings were taken at steady state after 2h of operation. Model predictions were then compared with experimental results by using the least squares algorithm. The moisture content was found to decrease along the flow field at the anode, but to increase at the cathode. The moisture content profile at the anode was shown to depend on the moisture Peclet number, which decreased with temperature. On the other hand, the moisture profile at the cathode was shown to depend on both the Peclet number and the Damkohler number. The trend of the Peclet number in the cathode followed closely that of the anode. The Damkohler number decreased with temperature, indicating increasing moisture mass transfer with temperature. The moisture profile models were successfully validated by the published data of the estimated overall mass transfer coefficient and moisture effective diffusivity of the same order of magnitude. The strategy of saturating the hydrogen feed and using dry air, as in the present work, has been shown to successfully prevent water droplet formation in the cathode, and hence prevent flooding.

    We also recommend Trading Suppliers and Manufacturers of Serpentine (cas 131-07-7). Pls Click Website Link as below: cas 131-07-7 suppliers


    Prev:Signal formation on a Serpentine (cas 131-07-7) delay-line electrode patterned on the CdZnTe detector
    Next: Of snakes and babies: intrathoracic stomach and vertebral rachischisis. A Serpentine (cas 131-07-7)-like syndrome?)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View