Encyclopedia

  • Polymeric membrane electrodes for selective determination of the central nervous system acting drugs FLUPHENAZINE HYDROCHLORIDE (cas 146-56-5) and nortriptyline hydrochloride
  • Add time:09/29/2019         Source:infona.pl

    The construction and electrochemical response characteristics of poly(vinyl chloride) (PVC), membrane sensors for determination of FLUPHENAZINE HYDROCHLORIDE (cas 146-56-5) and nortriptyline hydrochloride are described. The method is based on the formation of the ion-pair complexes between the two drugs cations and sodium tetraphenylborate (NaTPB) or tetrakis (4-chlorophenyl) borate (KtpClPB). Four poly(vinyl chloride) sensors were fabricated. For fluphenazine HCl sensors 1 and 3 were prepared using NaTPB and KtpClPB, respectively. For nortriptyline HCl sensors 2 and 4 were prepared using NaTPB and KtpClPB, respectively. They show linear responses for both drugs over the concentration ranges of 10 - 3 -10 - 5 , 10 - 2 -10 - 5 , 10 - 3 -10 - 5 and 10 - 2 -10 - 5 M with cationic slopes of 58.9, 52.5, 59.3 and 54.3mV per concentration decade, for sensors 1-4, respectively. The direct potentiometric determination of fluphenazine and nortriptyline hydrochlorides in their pure forms using the proposed sensors gave recoveries of 98.8+/-0.9, 99.0+/-0.9, 98.7+/-0.8 and 99.4+/-0.8% for sensors 1-4, respectively. This is compared reasonably with the data obtained using the British Pharmacopoeial method (1993). Sensors 1-4 were also used for determination of both drugs in their pharmaceutical dosage forms and in the presence of their degradates. It is noteworthy to mention that tetrakis (4-chlorophenyl) borate affects significantly the life time of the fabricated sensors of both drugs.

    We also recommend Trading Suppliers and Manufacturers of FLUPHENAZINE HYDROCHLORIDE (cas 146-56-5). Pls Click Website Link as below: cas 146-56-5 suppliers


    Prev:Second-Derivative Synchronous Fluorescence Spectroscopy for the Simultaneous Determination of FLUPHENAZINE HYDROCHLORIDE (cas 146-56-5) and Nortriptyline Hydrochloride in Pharmaceutical Preparations
    Next: FLUPHENAZINE HYDROCHLORIDE (cas 146-56-5) radical cation assay: A new, rapid and precise method to determine in vitro total antioxidant capacity of fruit extracts)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View