Propanamide,N,N-dimethyl-

1.IDENTIFICATIONOFTHESUBSTANCE/MIXTUREANDOFTHECOMPANY/UNDERTAKING
Product Name
-Dimethylpropionamide
2.HAZARDS IDENTIFICATION
Classification of the substance or mixture
According to Regulation (EC) No1272/2008
Acute toxicity, Oral (Category 4)
According to European Directive 67/548/EEC as amended.
Harmful if swallowed.
Label elements
Pictogram
Signal word
Hazard statement(s)
H302
Precautionary statement(s)
Hazard symbol(s)
Xn
R-phrase(s)
R22
S-phrase(s)
Warning
Harmful if swallowed.
none
Harmful
Harmful if swallowed.
none
Other hazards - none
3. COMPOSITION/INFORMATION ON INGREDIENTS
Formula
Molecular Weight
:
:
C5H11NO
101,15 g/mol
CAS-No.
EC-No.
Index-No.
Classification
Concentration
N,N-Dimethylpropionamide
758-96-3
212-064-9
-
Acute Tox. 4; H302
-
Xn, R22
For the full text of the H-Statements mentioned in this Section, see Section 16.
4. FIRST AID MEASURES
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing give artificial respiration Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
5. FIRE-FIGHTING MEASURES
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special protective equipment for fire-fighters
Wear self contained breathing apparatus for fire fighting if necessary.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions
Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up
Soak up with inert absorbent material and dispose of as hazardous waste. Keep in suitable, closed
containers for disposal.
7. HANDLING AND STORAGE
Precautions for safe handling
Avoid inhalation of vapour or mist.
Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic
charge.
Conditions for safe storage
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Personal protective equipment
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with
multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to
engineering controls. If the respirator is the sole means of protection, use a full-face supplied air
respirator. Use respirators and components tested and approved under appropriate government
standards such as NIOSH (US) or CEN (EU).
Hand protection
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the
standard EN 374 derived from it.
Handle with gloves.
Eye protection
Face shield and safety glasses
Skin and body protection
Choose body protection according to the amount and concentration of the dangerous substance at the
work place.
Hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at
the end of workday.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Form
Colour
Safety data
pH
Melting point
Boiling point
Flash point
Ignition temperature
Lower explosion limit
Upper explosion limit
Density
Water solubility
Partition coefficient:
n-octanol/water
Relative vapour
density
liquid
clear
no data available
-45 °C - lit.
174 - 175 °C - lit.
62 °C - closed cup
no data available
no data available
no data available
0,92 g/cm3 at 25 °C
no data available
log Pow: -0,018
3,49
- (Air = 1.0)
10. STABILITY AND REACTIVITY
Chemical stability
Stable under recommended storage conditions.
Conditions to avoid
no data available
Materials to avoid
Strong oxidizing agents
Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Carbon oxides, nitrogen oxides (NOx)
11. TOXICOLOGICAL INFORMATION
Acute toxicity
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC: No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Potential health effects
Inhalation
Ingestion
Skin
Eyes
May be harmful if inhaled. May cause respiratory tract irritation.
Harmful if swallowed.
May be harmful if absorbed through skin. May cause skin irritation.
May cause eye irritation.
Signs and Symptoms of Exposure
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly
investigated.
Additional Information
RTECS: UE3810000
12. ECOLOGICAL INFORMATION
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
PBT and vPvB assessment
no data available
Other adverse effects
no data available
13. DISPOSAL CONSIDERATIONS
Product
This combustible material may be burned in a chemical incinerator equipped with an afterburner and
scrubber. Observe all federal, state, and local environmental regulations. Contact a licensed professional
waste disposal service to dispose of this material.
Contaminated packaging
Dispose of as unused product.
14. TRANSPORT INFORMATION
ADR/RID
Not dangerous goods
IMDG
Not dangerous goods
IATA
Not dangerous goods
15. REGULATORY INFORMATION
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
16. OTHER INFORMATION
Text of H-code(s) and R-phrase(s) mentioned in Section 3
Acute Tox.
H302
Xn
R22
Acute toxicity
Harmful if swallowed.
Harmful
Harmful if swallowed.
Further information
The above information is believed to be correct but does not purport to be all inclusive and
shall be used only as a guide. The information this document is based on the resent state
of our knowledge and is applicable to the product with regard to appropriate safety precautions.
It does not represent any guarantee of the properties of the product. Lookchem shall not be
held liable for any damage resulting from handling or from contact with the above product.
See reverse side of invoice or packing slip for additional terms and conditions of sale.

;

Recommended suppliers

Tianjin Realet Chemical Technology Co.,Ltd.

China (Mainland) Assessed Supplier

N,N-Dimethylpropionamide

  • Assay:99.7% min
  • Appearance:colorless or light yellow liquid
  • Package:in 200kgs net drum or 950kgs IBC drum
  • Storage:kept in cool and ventilating place
  • Transportation:by sea, by air
  • Application:Used as than raw material of LCD stripper,electronic component clearing,semiconductor,pharmaceutical intermediates, and so on.
Contact Supplier

Hangzhou Ocean Chemical Co., Ltd.

China (Mainland) Assessed Supplier

NN-Dimethylproplonamide

  • Assay:tech grade,electronic grade,
  • Appearance:Colorless Or light Yellowish Liquid
  • Package:190Kg/drum or According to clients' requirement
  • Storage:Store in dry, cool and ventilated place
  • Transportation:If sample or samll quantity via Courier( FedEx/TNT) Shipment if commerical quantity ,via Air / Sea Shipment
  • Application:As organic intermediates, chemical reagents and etc.
Contact Supplier

HENAN NEW BLUE CHEMICAL CO.,LTD

China (Mainland) Assessed Supplier

NN-Dimethylproplonamide 758-96-3

  • Assay:99%
  • Appearance:off-white
  • Package:as per buyer's request
  • Storage:stored in a cool, dry and ventilated place
  • Transportation:NN-Dimethylproplonamide 758-96-3
  • Application:NN-Dimethylproplonamide 758-96-3
Contact Supplier

ZiBO KuoDing Trade company Ltd

China (Mainland) Assessed Supplier

N,N-Dimethylpropionamide

  • Assay:
  • Appearance:
  • Package:
  • Storage:
  • Transportation:
  • Application:
Contact Supplier

Dayang Chem (Hangzhou) Co.,Ltd.

China (Mainland) Assessed Supplier

N,N-Dimethylpropionamide Manufacturer/High quality/Best price/In stock

  • Assay:Industrial Grade,
  • Appearance:detailed see specifications
  • Package:according to the clients requirement
  • Storage:Store in dry, dark and ventilated place.
  • Transportation:by sea or by air
  • Application:It is an important raw material and intermediate used in Organic Synthesis, Pharmaceuticals, Agrochemicals and Dyestuff.
Contact Supplier

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View