88054-22-2 2-Methyl-5-nitroimidazole 99%2-Methyl-5-nitroimidazole
1.Compitive Price
2.Best price
3. Best after-sale service
Nanjing Chemipioneer Pharma&Tech Co.,Ltd founded in 2010, is a high-tech enterprise in pharma and chemical field, We mainly provide pharmaceutical raw materials and intermediates and also customize intermediates for clients home and aboard. We devote ourselves to researching, manufacture and selling services. We have set up steady and long-term cooperation relationship with pharmaceutical enterprises and research institutes.
Chemipioneer has own R&D center in Nanjing. From mg to kg, 10kg lot production can be done there. Chemipioneer also has the production base. The production base is located in Liuhe industrial district of Nanjing. Our manufactured products range from gram level to tonnage level.
From the day Chemipioneer founded, we base in home market and also scan widely to the international market. We can do chemical and pharmaceutical raw material and intermediates import and export trading independently. We have built long and firm cooperation relationship with lots of countries and regions such as India, Russia, Korea, South Africa, Europe countries and so on .
“To be honest and pragmatic, Customer first, To make effort and develop together ” is our mission. Hope more cooperation.
Product name |
2-Methyl-5-nitroimidazole |
Product number |
- |
Other names |
- |
Identified uses |
Industrial and scientific research uses. |
Uses advised against |
no data available |
Company |
chemicalbook |
Address |
D1517, Zijin Chemical Park, No. 606, Ningliu Road, Luhe District, Nanjing,Jiangsu,China |
Telephone |
86-25-52643182 |
Emergency phone number |
13914798241 |
Service hours |
Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
Not classified.
Pictogram(s) |
No symbol. |
Signal word |
No signal word |
Hazard statement(s) |
none |
Precautionary statement(s) |
|
Prevention |
none |
Response |
none |
Storage |
none |
Disposal |
none |
no data available
Chemical name |
Common names and synonyms |
CAS number |
EC number |
Concentration |
2-Methyl-5-nitroimidazole |
2-Methyl-5-nitroimidazole |
88054-22-2 |
618-108-7 |
100% |
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
no data available
Use dry chemical, carbon dioxide or alcohol-resistant foam.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
Physical state |
no data available |
Colour |
no data available |
Odour |
no data available |
Melting point/freezing point |
252-254ºC |
Boiling point or initial boiling point and boiling range |
0ºC |
Flammability |
no data available |
Lower and upper explosion limit/flammability limit |
no data available |
Flash point |
0ºC |
Auto-ignition temperature |
no data available |
Decomposition temperature |
no data available |
pH |
no data available |
Kinematic viscosity |
no data available |
Solubility |
no data available |
Partition coefficient n-octanol/water |
no data available |
Vapour pressure |
no data available |
Density and/or relative density |
no data available |
Relative vapour density |
no data available |
Particle characteristics |
no data available |
no data available
no data available
no data available
no data available
no data available
no data available
· Oral: no data available
· Inhalation: no data available
· Dermal: no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
· Toxicity to fish: no data available
· Toxicity to daphnia and other aquatic invertebrates: no data available
· Toxicity to algae: no data available
· Toxicity to microorganisms: no data available
no data available
no data available
no data available
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available |
IMDG: no data available |
IATA: no data available |
ADR/RID: no data available |
IMDG: no data available |
IATA: no data available |
ADR/RID: no data available |
IMDG: no data available |
IATA: no data available |
ADR/RID: no data available |
IMDG: no data available |
IATA: no data available |
ADR/RID: No |
IMDG: No |
IATA: No |
no data available
no data available
Chemical name |
Common names and synonyms |
CAS number |
EC number |
2-Methyl-5-nitroimidazole |
2-Methyl-5-nitroimidazole |
88054-22-2 |
618-108-7 |
European Inventory of Existing Commercial Chemical Substances (EINECS) |
Not Listed. |
||
EC Inventory |
Not Listed. |
||
United States Toxic Substances Control Act (TSCA) Inventory |
Not Listed. |
||
China Catalog of Hazardous chemicals 2015 |
Not Listed. |
||
New Zealand Inventory of Chemicals (NZIoC) |
Not Listed. |
||
Philippines Inventory of Chemicals and Chemical Substances (PICCS) |
Not Listed. |
||
Vietnam National Chemical Inventory |
Listed. |
||
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) |
Not Listed. |
||
Korea Existing Chemicals List (KECL) |
Not Listed. |
Creation Date |
July 15, 2019 |
Revision Date |
July 15, 2019 |
· CAS: Chemical Abstracts Service
· ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
· RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
· IMDG: International Maritime Dangerous Goods
· IATA: International Air Transportation Association
· TWA: Time Weighted Average
· STEL: Short term exposure limit
· LC50: Lethal Concentration 50%
· LD50: Lethal Dose 50%
· EC50: Effective Concentration 50%
· IPCS - The International Chemical Safety Cards (ICSC), website: #
· HSDB - Hazardous Substances Data Bank, website: #
· IARC - International Agency for Research on Cancer, website: #
· eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: # pageID=0&request_locale=en
· CAMEO Chemicals, website: #
· ChemIDplus, website: #
· ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: #
· Germany GESTIS-database on hazard substance, website: #
· ECHA - European Chemicals Agency, website: #
About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia
Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog
©2008 LookChem.com,License: ICP
NO.:Zhejiang16009103
complaints:service@lookchem.com Desktop View