Encyclopedia

  • Thermally condensed humic acids onto silica as SPE for effective enrichment of glucocorticoids from environmental waters followed by HPLC-HESI-MS/MS
  • Add time:08/06/2019         Source:sciencedirect.com

    Pristine humic acids (HAs) were thermally condensed onto silica microparticles by a one-pot, inexpensive and green preparation route obtaining a mixed-mode sorbent ([email protected]) with good sorption affinity for glucocorticoids (GCs). The carbon-based material, characterized by various techniques, was indeed applied as the sorbent for fixed-bed solid-phase extraction of eight GCs from river water and wastewater treatment plant effluent, spiked at different concentration levels in the range 1–400 ng L−1. After sample extraction, the target analytes were simultaneously and quantitatively eluted in a single fraction of methanol, achieving enrichment factor 4000 and 1000 in river water and wastewater effluent, respectively. Full recovery for all compounds, was gained in the real matrices studied (80–125% in river water, 79–126% in wastewater effluent), with inter-day precision showing relative standard deviations (RSD) below 15% and 18% (n = 3), for river and wastewater effluent, correspondingly. The high enrichment factors coupled with high-performance liquid chromatography tandem mass spectrometry quantification (MRM mode) provided method quantification limits of 0.009–0.48 ng L−1 in river water and 0.06–3 ng L−1 in wastewater effluent and, at the same time, secure identification of the selected drugs. As also evidenced by comparison with literature, [email protected] proved to be a valid alternative to the current commercial sorbents, in terms of extraction capability, enrichment factor, ease of preparation and cost. The batch-to-batch reproducibility was assessed by recovery tests on three independently prepared [email protected] powders (RSD lower than 7%).

    We also recommend Trading Suppliers and Manufacturers of Fluocinolone Acetonide-21-carboxylic Acid (cas 106931-78-6). Pls Click Website Link as below: cas 106931-78-6 suppliers


    Prev:Reduction of l
    Next: Immunohistochemical localization of thymopoietin with an antiserum to synthetic Cys-thymopoietin28–39)

About|Contact|Cas|Product Name|Molecular|Country|Encyclopedia

Message|New Cas|MSDS|Service|Advertisement|CAS DataBase|Article Data|Manufacturers | Chemical Catalog

©2008 LookChem.com,License: ICP

NO.:Zhejiang16009103

complaints:service@lookchem.com Desktop View