Add time:08/28/2019 Source:sciencedirect.com
A new chemiluminescence (CL) flow-injection method is proposed for the determination of 1,3-Dichloro-5,5-dimethylhydantoin (cas 118-52-5) (DDH). The method is based on the chemiluminescent reaction of DDH and luminol–H2O2 in an alkaline medium (pH 12.0–12.5). The concentration of the analyte shows a good linear relationship with the produced luminescence intensity in the range of 3.0×10−8 to 8.0×10−6 mol l−1. The detection limit of the proposed method is 1.0×10−8 mol l−1 and the relative standard deviation (R.S.D.) is 4.7% (n=5) at 5.0×10−7 mol l−1. This method was successfully applied to the determination of trace amounts of this disinfectant in water samples obtained from five different swimming pools. Satisfying recovery values were also obtained.
We also recommend Trading Suppliers and Manufacturers of 1,3-Dichloro-5,5-dimethylhydantoin (cas 118-52-5). Pls Click Website Link as below: cas 118-52-5 suppliers